Pump Protector for Submersible Pumps, with Enclosure
The Model 233-P single-phase Pump Saver Plus is a pump monitor designed to protect single-phase pumps from dry-well, dead-head, jammed impeller, rapid cycle and overvoltage and undervoltage conditions. The Pump Saver Plus Model 233-P protects 230 volt, 2 or 3 wire, 1/3 to 1.5 hp pumps.
A calibration adjustment allows the Model 233-P to be calibrated to your
specific pumping applications, thereby reducing the possibility of false or
nuisance tripping. A proprietary microcontroller based voltage, power factor
and current-sensing circuit constantly monitors for power fluctuations,
overcurrent and underload conditions. When an abnormality, such as loss
of suction, is detected, the PumpSaverPlus deactivates its output relay
and directly disconnects the pump motor. The PumpSaver®Plus then begins its
user-selectable “Restart Delay” (dry-well recovery) timer. When the timer
expires or power is removed and reapplied, the PumpSaver®Plus reactivates its
output relay and turns the pump back on.
Product Features
The Pump protectors models have a sensitivity adjustment
for the dry-well trip point. After calibration is done, you can adjust the
sensitivity for the dry-well/dead-head trip point from 70-90% of the full load.
This makes the unit even more adaptable to varying pumping applications. If you
have a very low producing well, you increase the sensitivity closer to the 90%
mark, or if you have a very heavy producing well, you would decrease the
sensitivity around the 70% mark.
PUMP PROTECTION AT ITS BEST
For Franklin 2 & 3-wire single-phase motors, 1/3 to 1.5 hp, 115V or
230V
The facts are clear and so are the choices. Franklin pump controls boxes provides the high
performance pump protection you need deep down in the well. Designed to monitor
motor load and supply voltage and to shut down the pump to prevent damage,
Pumptec family products protect you water system investment.
PUMPTEC
Pumptec is a microcomputer-based pump protection device. It monitors motor
load and power line conditions to provide protection against dry well
conditions, waterlogged tanks, and abnormal line voltage conditions. Pumptec
interrupts power to the motor whenever the load drops quickly or below a preset
level. Indicator lights on the cover provide complete system status.
Additional features
- Easily adjustable
sensitivity settings
- Run and fault
indicator lights
- Heavy duty relay
- Alarm circuit
contacts
- Remote control
options
- UL/CSA Listed
Comments