Pump Protector for Submersible Pumps, with Enclosure

 The Model 233-P single-phase Pump Saver Plus is a pump monitor designed to protect single-phase pumps from dry-well, dead-head, jammed impeller, rapid cycle and overvoltage and undervoltage conditions. The Pump Saver Plus Model 233-P protects 230 volt, 2 or 3 wire, 1/3 to 1.5 hp pumps.


A calibration adjustment allows the Model 233-P to be calibrated to your specific pumping applications, thereby reducing the possibility of false or nuisance tripping. A proprietary microcontroller based voltage, power factor and current-sensing circuit constantly monitors for power fluctuations, overcurrent and underload conditions.  When an abnormality, such as loss of suction, is detected, the  PumpSaverPlus deactivates its output relay and directly disconnects the pump motor. The PumpSaver®Plus then begins its user-selectable “Restart Delay” (dry-well recovery) timer. When the timer expires or power is removed and reapplied, the PumpSaver®Plus reactivates its output relay and turns the pump back on.

Product Features

The Pump protectors models have a sensitivity adjustment for the dry-well trip point. After calibration is done, you can adjust the sensitivity for the dry-well/dead-head trip point from 70-90% of the full load. This makes the unit even more adaptable to varying pumping applications. If you have a very low producing well, you increase the sensitivity closer to the 90% mark, or if you have a very heavy producing well, you would decrease the sensitivity around the 70% mark.



PUMP PROTECTION AT ITS BEST

For Franklin 2 & 3-wire single-phase motors, 1/3 to 1.5 hp, 115V or 230V

The facts are clear and so are the choices. Franklin pump controls boxes provides the high performance pump protection you need deep down in the well. Designed to monitor motor load and supply voltage and to shut down the pump to prevent damage, Pumptec family products protect you water system investment.




PUMPTEC

Pumptec is a microcomputer-based pump protection device. It monitors motor load and power line conditions to provide protection against dry well conditions, waterlogged tanks, and abnormal line voltage conditions. Pumptec interrupts power to the motor whenever the load drops quickly or below a preset level. Indicator lights on the cover provide complete system status.

Additional features

  • Easily adjustable sensitivity settings
  • Run and fault indicator lights
  • Heavy duty relay
  • Alarm circuit contacts
  • Remote control options
  • UL/CSA Listed